Description
JDS2800 AC100-240V DDS Function Arbitrary Waveform Signal Generator Software(60MHz )
JDS2800 series Dual-channel Function Signal generator combines multiple functions in one, such as Function Signal Generator, Arbitrary Waveform Generator, Pulse Generator, Sweep, Counter and Frequency Meter, etc. The instrument adopts the Direct Digital Synthesizer(DDS) technology and provides stable, precise, pure and low distortion signals. It's a great testing or measuring instrument for electronics engineers, electronic laboratory, teaching and researching.Features:1. Adopt 320*240 2.4" TFT color LCD display, simultaneously display parameters of CH1 and CH2; Ability to reproduce patterns of custom waveform;2. Use soft silicone keys instead of traditional patch keys, high sensitivity and convenient for operation; 3. Max. output frequency(sine wave) up to 15MHz/40MHz/60MHz(optional), 266MSa/s sampling rate and 14bits vertical resolution4. Completely independent dual channels output, synchronizing operation and adjustable phase difference5. Great improvement for square wave performance, square frequency range up to 25MHz with no distortion6. 60 groups of arbitrary wave storage function, memory depth of each group is 2048*14bits; 7.High frequency accuracy and resolution: frequency accuracy up to 10(-6) magnitude, total range frequency resolution is 0.01uHz8. High amplitude resolution: the minimum amplitude resolution can reach 1mV, amplitude range is 0Vpp~20Vpp9.Duty-cycle of each channel can be adjusted independently, the adjusting resolution is 0.1%10.Sweepfunction: linear sweep and logarithmic sweep functions; 0.1s-999.9s sweep time, forward, backward and roundtrip sweep directions 11.With pulse trains burst output function: allow the unit output 1~1048575 arbitrary pulse trains 12.Measurementfunctions: can measure signal frequency, cycle, positive/negative pulsewidth and duty cycle; 1Hz~100MHz frequency range 13.-9.99V~9.99V DC offset range, offset resolution: 0.01V 14.With digital signal output function, CMOS output range 0~10V 15.Storage feature: can store 100 groups of parameters set by the user and extract at any time Counter function: with DC and AC coupling modes 16.Arbitrary wave editing function: user can edit arbitrary wave on PC and then download to output from the instrument 17.Communication function: the PC can be used to control the instrument18. With output short-circuit protection: all signal output can work 60s under load short-circuit conditionSpecification:Voltage:AC100-240VType: 60MHz EU plugJDS2800-15MHzFrequency specifications:Sine frequency range: 0~15MHz Square frequency range: 0~15 MHz Triangle frequency range: 0~15MHz Pulse frequency range: 0~6 MHz TTL digital frequency range: 0~6 MHz Arbitrary wave frequency range: 0~6 MHz Square rise time: 25nS Pulse width adjustment range: 100nS - 4000S Frequency accuracy: 20 ppm Frequency stability: 1 ppm/3h JDS2800-40MHzFrequency specifications:Sine frequency range: 0~40MHzSquare frequency range: 0~25 MHzTriangle frequency range: 0~25 MHzPulse frequency range: 0~6 MHzTTL digital frequency range: 0~6 MHzArbitrary wave frequency range: 0~6 MHzSquare rise time:10nSPulse width adjustment range: 40nS- 4000SFrequency accuracy:20 ppmFrequency stability:1 ppm/3hJDS2800-60MHzFrequency specifications:Sine frequency range: 0~60MHzSquare frequency range: 0~25 MHzTriangle frequency range: 0~25 MHzPulse frequency range: 0~6 MHzTTL digital frequency range: 0~6 MHzArbitrary wave frequency range: 0~6 MHzSquare rise time:10nSPulse width adjustment range: 25nS- 4000SFrequency accuracy:20 ppmFrequency stability:1 ppm/3hThe following technical indicators are the same for all 3 modelsWaveform specifications:Waveform: Sine, square, triangle, pulse (duty-cycle correction, pulse width and cycle time adjustable), arbitrary wave, CMOS, DC level, half-wave, full-wave, pos-ladder, neg-Ladder, noise, exponential rise, exponential fall, tone, cink pulse, lorentz pulse, and 60 kinds user-defined waveforms.Waveform vertical resolution: 14 bitsWaveform sampling rate: 266 MSa/sWaveform length: 2048 pointsSine- Harmonic suppression: 45dBc(<1 MHz);40dBc(1 MHz~20 MHz)Sine- Total harmonic distortion: <0.8%(20 Hz~20 kHz,0dBm)Square and Pulse- Overshoot (Square): 5%Square and Pulse- Duty-cycle range(Pulse):0.1- 99.9%Ramp wave-Linearity: 98%(0.01 Hz~10 kHz)Output specifications:Amplitude range: Frequency<10MHz,0-20VPP; Frequency10 MHz, 0- 10Vpp.Amplitude resolution: 1 mVAmplitude stability: 0.5%/5 hAmplitude flatness: 5%(<10 MHz);10%(>10 MHz)Waveform specifications:Output impedance: 5010%typicalProtection: Short circuit 60S will not be damagedDC Offset:Offset adjusting range: Output Amplitude>2V,-9.99V~9.99V;0.2V<Output Amplitude2V,-2.5V~2.5V;0Output amplitude0.2V,-0.25V~0.25VOffset resolution: 0.01 VPhase specifications:Phase adjusting range: 0~359.9oPhase resolution: 0.1oTTL/COMS Output:Low level: <0.3 VHigh level: 1- 10 VLevel rise/fall time: 20nsExternal measurement functions:Frequency meter function- Frequency measurement range: 1 Hz~100 MHzFrequency
-
Fruugo ID:
387493470-831850986
-
EAN:
6950044994640
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Product Safety Labels
Safety Warnings:
Replacement must be performed with the assistance of a professional
Ingredients:
75% plastic and 25% metal