K24 Chemical Flowmeter, Urea Flowmeter, Methanol Flowmeter

£79.00
+ £9.49 Shipping

K24 Chemical Flowmeter, Urea Flowmeter, Methanol Flowmeter

  • Brand: Unbranded
Sold by:

K24 Chemical Flowmeter, Urea Flowmeter, Methanol Flowmeter

  • Brand: Unbranded

£79.00

Save £50.00 (38%)

RRP

£129.00
In stock
+ £9.49 Shipping

14-Day Returns Policy

Sold by:

£79.00

Save £50.00 (38%)

RRP

£129.00
In stock
+ £9.49 Shipping

14-Day Returns Policy

Payment methods:

Description

K24 Chemical Flowmeter, Urea Flowmeter, Methanol Flowmeter

Features: The chemical flow meter control panel is modular in design. It has complete functions, convenient operation and simple structure. The large LCD display facilitates clear reading. Can be used to measure methanol, kerosene, diesel, fuel, urea water. Widely used in petroleum, chemical, pharmaceutical, transportation, food industry and commercial fields. Specifications: Model: K24 Fluid: Methanol, Diesel, Fuel, Kerosene, Urea Water Inlet/Outlet Thread: G1 (BSPP) Measurement Accuracy: 1% Repeatability: 0.5% Maximum Pressure: 20BAR Working Voltage: 2.3-3.3V Standby Time: 2 years Flow range: 10-120L/MIN Single count: 0.00-999.9 Total count: 0.00-999999.9 Command: 1. The measurement unit is set in the standby state or the current volume display state, press and hold the MENU + RESET button for 5 seconds to enter the unit conversion setting, then press the RESET button to select LTR-GAL-PT-QT-LTR in sequence. Press and hold the MENU button for 3 seconds to exit the unit conversion setting. 2. Accumulation and current reset Press and hold the RESET button, the LCD screen will display in full screen, wait until the full screen display ends, and then release the RESET button. At this time, the accumulated amount and the current amount are reset. 3. Inquiry of error coefficient and accumulated amount In standby state, press MENU + RESET buttons simultaneously, then the LCD display will display the error coefficient on the upper line and the accumulated amount on the next line. 4. Error coefficient calibration In the standby state or the current quantity display state, press and hold the MENU button for 3 seconds to enter the error coefficient calibration mode. The first digit flashes, press the MENU button to change the digit position, then press the RESET button to change the digit. As the coefficient increases, the oil output decreases. Then press and hold the MENU button for 3 seconds to end the error coefficient calibration and return to the current volume display state, and the current volume is reset to zero. The calibration error coefficient range is 0.1000 to 9.9999. For example, the original coefficient is 1.000, when it shows the oil output of 100 liters, the actual oil output is 100 liters. If you need to reduce 2 liters, set the factor to 1.020 and the output is 98 liters. 5. Maintenance When the battery voltage is too low, a battery symbol will appear on the LCD to remind the user to replace the battery. Short battery life can damage the meter due to battery leakage. The meter is designed to last about two years, but we recommend that customers replace the battery once a year and check the battery electrodes for rust. If the flowmeter will not be used for a long time, the battery should be removed.
  • Fruugo ID: 215554367-459701054
  • EAN: 1063762898185

Delivery

Dispatched within 3 days

  • EXPRESS: £9.49 - Delivery between Tue 23 June 2026–Mon 06 July 2026

Shipping from China.

Returns

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items.

View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • Foshan Goris Trading
  • Foshan Goris Trading Co. , Ltd
  • Room C, Room 1309, Building 1, No. 18, Fenjiang South Road, Shiwan Town, Chancheng District
  • Foshan
  • China
  • 528000
  • [email protected]
  • 15362877422
  • https://www.qcc.com/firm/89458faebcd8eddb5b0c280da2cb2deb.html

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • Sophie Dupont
  • PROCONSEIL FR
  • 8 bis rue Abel 75012 Paris
  • 8 bis rue Abel 75012 Paris, France
  • Paris
  • France
  • 75012
  • [email protected]
  • 0780843245
  • https://www.proconseilfr.com