Pocket Portable Digital pH Meter Tester Water Quality Testing for Swimming Pool Aquarium

£11.77
+ £8.40 Shipping

Pocket Portable Digital pH Meter Tester Water Quality Testing for Swimming Pool Aquarium

  • Brand: Unbranded
Sold by:

Pocket Portable Digital pH Meter Tester Water Quality Testing for Swimming Pool Aquarium

  • Brand: Unbranded

£11.77

Save £11.79 (50%)

RRP

£23.56
In stock
+ £8.40 Shipping
Sold by:

£11.77

Save £11.79 (50%)

RRP

£23.56
In stock
+ £8.40 Shipping

We accept the following payment methods

Description

Features1Waterproof metal electrode and material, not easy to break and durable in use. 2Easy to use and operate, just insert the probe into the liquid and press the button for pH testing. 3Compact structure, lightweight and portable, easy to carry and convenient for indoor and outdoor use. 4Suitable for measuring the pH value of aquarium, fishing, swimming pool, school laboratory, food and beverage. 5This digital pH meter features high accuracy, stable measurement, high reliable and performance.SpecificationCondition: 100% Brand NewItem Type: pH MeterMaterial: PlasticWorking Temperature: 0-50 RH95% (32-122)Measuring pH Range: 0.0-14.0pHResolution: 0.1pHAccuracy: 0.2pH (at 20) / 0.2pHBattery: 4 x 1.5V Button Battery (Not Included)Product Size: Approx. 3.1 x 1.6 x 15 cm / 1.2 x 0.6 x 5.9 inWeight: Approx. 120g / 4.2ozOperating Steps:1. Remove the protective cover.2. Firstly, the electrode of the pH meter should be cleaned with distilled water, and wipe the electrode with filter paper.3. Turn on the power button located on the battery compartment.4. Insert the pH meter into the liquid to be measured until the liquid is immersed in the ''immersion line''. If condition allowed, the solution can be immersed slightly above the ''immersion line''.5. Stir the solution gently and wait for about two minutes, and then read the displayed value.6. After use, the electrode should be cleaned, turn off the power and put on the protective cover.pH Tester Calibration:1. Put the pen into the pH6.86 calibration buffer, the height of the buffer solution should not exceed the height of the pen cover, but it must be higher than the electrode.2. Gently stir the pen in the buffer and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and no longer changes. Use a screwdriver to aim the correction button (The small hole on the back), slowly adjust to a reading of 6.86, and then let it stand for about 5 seconds until the reading is stable, that is, the calibration is successful. Note: (Each measurement process needs to be rinsed with tap water).3. Put the pen into the pH4.0 calibration buffer, the height of the buffer solution should not exceed the height of the pen cover, but it must be higher than the electrode.4. Gently stir the pen in the buffer and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and no longer changes. Use a screwdriver to aim the correction button (The small hole on the back), slowly adjust to a reading of 4.0, and then let it stand for about 5 seconds until the reading is stable, that is, the calibration is successful.pH Tester Maintenance:1. When there is white crystal on the pen tip, this is normal, don't be nervous, you can soak it in water for a while.2. Remove the pen cover and turn on the power, it is normal for the digits jumping in the air.3. Put the pen into the solution to be tested, the height of the solution cannot be higher than the height of the pen cover, but it must be higher than the electrode.4. Regularly calibrate the PH tester. Generally, it needs to be re-calibrated every three months.5. After calibration, gently stir the pen in the solution to be tested and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and does not change. The reading now is the correct pH.6. After use, immerse the pen tip electrode in water and wash off the test solution on the electrode. Do not flush the other parts, then cover the pen cover back, and turn off the power.Package List1 x pH Meter (Battery Not Included) 1 x User Manual 2 x pH Calibration Powder 1 x Screwdriver
  • Fruugo ID: 399162744-850052283
  • EAN: 7689049410426

Product Safety Information

Please see the product safety information specific to this product outlined below

The following information is provided by the independent third-party retailer selling this product.

Safety Warnings: Do not suitable for children under 36 months.

Delivery & Returns

Dispatched within 3 days

  • STANDARD: £8.40 - Delivery between Tue 18 November 2025–Tue 25 November 2025

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611