XH-W3002 220V /12V Digital LED Temperature Controller 10A Thermostat Control Switch Probe with waterproof sensor W3002

£21.40
+ £7.20 Shipping

XH-W3002 220V /12V Digital LED Temperature Controller 10A Thermostat Control Switch Probe with waterproof sensor W3002

  • Brand: Unbranded
Sold by:

XH-W3002 220V /12V Digital LED Temperature Controller 10A Thermostat Control Switch Probe with waterproof sensor W3002

  • Brand: Unbranded

£21.40

Save £93.60 (81%)

RRP

£115.00
In stock
+ £7.20 Shipping

14-Day Returns Policy

Sold by:

£21.40

Save £93.60 (81%)

RRP

£115.00
In stock
+ £7.20 Shipping

14-Day Returns Policy

Payment methods:

Description

XH-W3002 220V /12V Digital LED Temperature Controller 10A Thermostat Control Switch Probe with waterproof sensor W3002

XH-W3002 220V /12V Digital LED Temperature Controller 10A Thermostat Control Switch Probe with waterproof sensor W3002 Product Description: Name:Microcomputer temperature controller Product Model:XH-W3002 Temperature range:-50~110. Temperature control range:-50~110 Temperature measurement accuracy: 0.2 Temperature control accuracy: 0.1. Measurement input: NTC10KL = 1 meter waterproof probe Input power:12/24/220V Output power: 120/240/1500W Output type: direct output Output capacity: 10A max Mounting hole distance: 73mm (hole diameter 4mm) P0 Set the startup temperature: Press the setup button to enter the internal menu, the default display is P0, press the setup button again to set the desired start temperature by pressing the up and down buttons. P1 Setting stop temperature: Press the setup button to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setup button again and set the desired stop temperature by pressing the up and down buttons. P2 Setting temperature correction: The same way to enter the internal menu, switch to P2 by up and down buttons, press the setup key again, set the desired calibration temperature by up and down buttons. In the setting, if the detected temperature value is 0.5 larger than the actual temperature value, then the calibration temperature to be set is -0.5. If the detected temperature value is 1 smaller than the actual temperature value, the calibration temperature to be set is 1. Detection temperature calibration temperature = actual temperature. P3 Setting delayed start: The same way into the internal menu, through the up and down keys to switch to P3, once again press the setup key, through the up and down keys to set the required delay time (unit is minutes). Delay start is generally used for compressor refrigeration, if used in refrigerators and freezers, this value needs to be set, according to the size of the compressor back to the general set value of 3-6 minutes, if you are not used to control the compressor or do not need to delay the function, directly skip this item. Heating mode setting mode: Setting: start temperature < stop temperature (the program automatically determines the mode of operation for the heating mode) Setting method. Press the setup key to enter the internal menu, set the start temperature by setting the P0 value, set the stop temperature by setting the P1 value. Use case: Control the water heater, heating to 50 to stop, the temperature falls back to 40 to start heating again, how to set? Step 1: Make sure the working mode is heating mode, start temperature < stop temperature Step 2: Press setup key to enter the internal menu, select P0 and press setup key to set P0 value to 40 Step 3: Press setup key to enter the internal menu, select P1 and press setup key to set P1 value to 50. Cooling mode setting mode: Setting key:Start temperature>Stop temperature (the program automatically determines the working mode as refrigeration mode) Setting mode: Press setup key to enter internal menu, set start temperature by setting P0 value, set stop temperature by setting P1 value. Use case. Control cabinet radiator, heat dissipation to 26 to stop, the temperature rises to 30 to start the radiator again, how to set? Step 1: Make sure the working mode is cooling mode, start temperature > stop temperature. Step 2:Press Setup to enter the internal menu, select P0 and press Setup to set the P0 value to 30. Step 3:Press setup button to enter internal menu, select P1 and press setup button, set P1 value to 26. Tip: When setting the heating mode, if you don't set the heating mode, you can set the value of P1 to 26. When setting the heating mode, if the set temperature value is inverted accidentally, the output indicator will not light up and the load will not work, if the above situation occurs after the setting is completed, you can check whether the set temperature value is inverted or not. _x000D_ _x000D_
  • Fruugo ID: 352423983-767459328
  • EAN: 7248431357093

Product Safety Information

Please see the product safety information specific to this product outlined below

The following information is provided by the independent third-party retailer selling this product.

Product Safety Labels

CE Mark
Safety Warnings: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Ingredients: Octinoxate 5.677%
Manufacturer Part Number: YY077139
Model Number: YY333728
Serial Number: YY309817
Batch Number: YY001517

Delivery & Returns

Dispatched within 3 days

  • STANDARD: £7.20 - Delivery between Tue 06 January 2026–Wed 14 January 2026

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy